• Loavto Spa

HEATING INTERFACE UNITS

Lovato Spa
MACUK NEW
MACUK Nuovo Isolamento EPP
INDIRECTA NEW
INDIRECTA CTU e HTU
GUIDA ALLA SCELTA
GUIDE
tiger_1a
TIGER-1 – Heat interface unit – Metering & Temperature Control
AV MODUL 1 POLLICE
AV MODUL 1″ – Heat interface unit HIU – Energy Metering & Temperature Control
AV MODUL LUNGO
AV MODUL 3/4″ – Heat interface unit HIU – Energt Metering & Temperature Control
cp mono 3d erp
CP-MONO – Heat interface unit HIU – Metering & Temperature Control
49095115
CP DUAL – Heat interface unit HIU – Energy Metering & Temperature Control
rsm 007
MACUK RSM – Heat interface unit HIU – Energy Metering & Temperature Control
rsd 001
MACUK RSD – Heat interface unit HIU – Energy Metering & Temperature Control
s-sr nuovo 001
MACUK S-SR – Heat interface unit HIU – Energy Metering & Temperature Control
CONTABILIZZAZIONE
M-BUS ENERGY METERING
EYRON
EYRON – M-BUS COMPACT ENERGY METERING
Contabilizzatore LVT5
LVT/5 – MBUS COAXIAL ENERGY METERING
MULTIDATA LOVATO WR3
WR3 MULTIDATA – Metering system in boiler room
CONTABILIZZAZIONE
Energy metering in boiler room
KIT BE-Q CK-D
BE-Q CK-D – Counting kit KA DN25 / KS DN25
BE-Q CK-M
BE-Q CK-M – Counting kit KTC DN25 / KM3 DN25
ENERGY COUNTER KIT ULTRASONIC
ULTRASONIC Energy Counter KIT MID Directive
ENERGY KIT FLANGIATO
ULTRASONIC Energy Counter KIT MID Directive
ENERGY KIT
Mthisplit – Energy Counter KIT MID Directive
Volumetrico ACS
SINGLE-JET VOLUMETRIC METER FOR DOMESTIC HOT WATER
CONTATORE VOL AFS
SINGLE-JET VOLUMETRIC METER FOR DOMESTIC COLD WATER
CONTATORE VOLUMETRICO ACS LITTL
MULTI-JET VOLUMETRIC METER FOR DOMESTIC HOT WATER
CONTATORE VOLUMETRICO AFS BIG
MULTI-JET VOLUMETRIC METER FOR DOMESTIC COLD WATER
AFS ACS BASIC
VOLUMETRIC METERS BASIC FOR HOT/COLD DOMESTIC WATER
Contatore Volumetrico ACS
VOLUMETRIC COUNTERS MULTI-JET WOLTMANN ACS
ENERGY KIT WOLTMANN
WOLTMANN – Energy Counter KIT MID Directive
ATATTATORE MBUS
M-BUS PULSE ADAPTER/CONVERTER MODULE
Trasmettitore
RADIO PULSE ADAPTER/CONVERTER M-BUS
SONDE
Sensor pocket DN32/200
MACUK NEW

MACUK Nuovo Isolamento EPP

COMING SOON

Vieni a vederlo in anteprima a:

MCE 2018
Fieramilano 13-16 marzo 2018
HALL 2 – STAND K33 L32

 

INDIRECTA NEW

INDIRECTA CTU e HTU

COMING SOON

Vieni a vederlo in anteprima a:

MCE 2018
Fieramilano 13-16 marzo 2018
HALL 2 – STAND K33 L32

 

GUIDA ALLA SCELTA

GUIDE

LOVATO_CONTABILIZZAZIONE_GUIDA4

tiger_1a

TIGER-1 – Heat interface unit – Metering & Temperature Control

TIGER 1 is a compact energy metering module and users management suitable for different types of plants.

It is particularly recommended for plants with thermostatic regulation.

 

ADVANTAGES

• Multifunction valve 5 in 1 FLOWBLOCK

• Energy metering with automatic recognition of the heating/cooling modality

• Possibility to connect up to 3 volumetric meter with pulse exit

• Compact size: 400 x 450 x 110 mm (WxHxD)

• Acoustic/thermal insulation suitable for heating and cooling systems

• Vertical or horizontal installation through specific spacer

 

 

FLOW BLOCK

FLOWBLOCK 5+1

The multifunction valve is equipped with a cartridge which has to be pre-set using the proper given key, regulating the grading scale on the upper side.

It is possible to choose up to 37 pre-set values for the valve.

Once the planned flow rate value is set the balance will be automatic and it will never exceed the value set.

 

Zone valve regulation :

– 230V actuator for the ON-OFF regulation from the min. to the max. value set
– 24V actuator for the ON-OFF regulation from the min. to the max. value set

 

The FLOWBLOCK multifunction valve includes:

– Filter
– Volumetric meter sensor seat
– Zone valve
– Automatic balancing valve: settable flow rate from 200 to 1.175 l/h
– Differential valve on the plant side which permits to bypass the return vector fluid as the pressure of the plant rises
Calibration 1.900 mm H2O

 

LOVATO_Contabilizzazione Energia_Tiger 1_con coperchio

• DOOR – FRAME WITH SELF-ADJUSTABLE DEPTH REGULATION

 

 

LOVATO Tiger1_contabilizzazione_energia_schema sovrapposizione

METERING IN THE STAIR WELL AND USER MANAGEMENT INTO THE DWELLING

TIGER_LOVATO_SCHEMA4

AV MODUL 1 POLLICE

AV MODUL 1″ – Heat interface unit HIU – Energy Metering & Temperature Control

LOVATO AV-MODUL 1″ – Heating interface units.

AV-MODUL is an energy metering module and users management, composed of several modules which, when properly combined, satisfy different type of plants.

Upon request special modules may be produced up to 1½” (DN 40).

 

ADVANTAGES

• Management of a single zone with a 2 or 3-way valve ready for the consumption management as the AV-MODUL 1” version.

• Energy metering with automatic recognition of heating/cooling modality

• DHW and DCW connection with straight or curved valves.

• Box depth 110 mm.

• Thermal/acoustic insulation suitable for heating and cooling systems

AV MODUL LUNGO

AV MODUL 3/4″ – Heat interface unit HIU – Energt Metering & Temperature Control

AV-MODUL 3/4″ is an energy metering module and users management, composed of several modules which, when properly combined, satisfy different type of plants.

 

ADVANTAGES

• Management of 2 or more zones of a thermal plant with two different temperature levels

• Mixing regulation at fixed point or at variable temperature

• Energy counter with automatic recognition of heating/cooling modality

• DHW and DCW exit connection with straight or curved valves

• Box depth 110 mm

• Thermal/acoustic insulation suitable for heating and cooling systems


 

METERING IN STAIR WELL AND USER MANAGEMENT INTO THE DWELLING:

 

LOVATO_AV-MODUL-SCH A-EN

LOVATO_AV-MODUL-SCH B-EN

LOVATO_AV-MODUL-SCH C-EN

 

cp mono 3d erp

CP-MONO – Heat interface unit HIU – Metering & Temperature Control

CP-MONO is a single zone metering and user management system with hydraulic separator.

 

• WILO YONOS PARA 15/1-6 ERP READY

 

ADVANTAGES

• User management with circulation pump

• Hydraulic separator with automatic airvent and drain valve

• Energy meter

• DHW and DCW exit connection with straight valves

• Box depth 110 mm 110 mm (Dimensions BxHxP 600x650x110 mm)

• Thermal/acoustic insulation suitable for heating and cooling systems (on request)

 

COMPONENTS

1 – Primary side unit:

composed of: supply ball valve ¾”, balance valve ¾”, spacer connection, return ball valve ¾”, seals, tracks fixing kit.

 

2 – Hydraulic separator:

Built with a steel double chamber profile ST37.1, hydraulically tested and painted with water-based ecological paint. Automatic vent valve and drain valve are included.

 

3 – Distribution unit:

Composed of: Wilo YONOS PARA 15/1-6 circulation pump, check valve, Y shaped filter, delivery ball valve ¾” with M10 pocket for supply sensor, return ball valve ¾”, EAS support, piping kit, seals.

 

4  – Kit DHW meter with the exit on the lower side
5 – Kit DCW meter with the exit on the lower side
6 – Recessed box

 

49095115

CP DUAL – Heat interface unit HIU – Energy Metering & Temperature Control

CP-DUAL is a double zones metering and user management system with hydraulic separator.

 

• WILO YONOS PARA 15/1-6 ERP READY

 

ADVANTAGES

• User management of up to 2 zones

• Distribution manifold with integrated hydraulic separator.

• Mixing/diverting valve for zone management, ready for ON-OFF actuator, thermostatic actuator or electrical servomotor (high temperature management with on/off valves or low temperature management with mixing valve at fixed point or variable temperature).

• Energy metering

• DHW and DCW connection with straight valves

• Box depth 110 mm (BxHxP 800x650x110 mm)

• Thermal/acoustic insulation suitable for heating and cooling systems (upon request)

 

COMPONENTS

1- Heating interface unit:

composed of: ball valve ¾” with check valve, 1”x130 mm temporary jig, ball valve ¾”, delivery ball valve ¾”w ith built-in filter, balance valve ¾”, ball valve ¾” with M10 adapter for delivery probe, s eals, tracks fixing kit.

2- Hydraulic separator manifold:

Built with a steel double chamber profile ST37.1, hydraulically tested and painted with water-based ecological paint. Automatic vent valve and drain valve are included.

3- Distribution unit:

Mixing/diverting valve DN 20 Kv=5, pump Wilo YONOS PARA 15/1-6, 2 shut-off valves, piping kit, seals.

4- Distribution unit:

Mixing/deviating valve DN 20 Kv=5, pump Wilo YONOS PARA 15/1-6, 2 shut-off valves, piping kit, seals.


5- Kit DHW meter with the exit on the lower side
6- Kit DCW meter kit with the exit on the lower side
7- insulated built-in box

 

 

 

METERING IN STAIR WELL AND USER MANAGEMENT INTO THE DWELLING:

LOVATO_CP-DUAL_SCH_A-4

LOVATO_CP-DUAL_SCH_B-4

rsm 007

MACUK RSM – Heat interface unit HIU – Energy Metering & Temperature Control

MACUK RSM is a substation for heating and instantaneous domestic hot water.

It is suitable for apartments, single family house and central heating systems.

Its installation is fast and easy. It is ready to be connected with the hydraulic connections on the premises.

Heating function + DHW function.

 

Several accessories are available to fulfill all requirements.

- heat meter and cold water meter with pulse exit M-Bus ready
- heat meter and cold water meter with radio transmitter
- ultrasonic heat meter
- thermostatic kit 20-50°C suitable for low temperature heating systems
- thermostatic kit 40-70°C suitable for high temperature heating systems
- electronic control kit consisting of: electric servomotor 230V, digital heating controller and remote control with room sensor.

The production of domestic hot water is controlled by a proportional thermostatic valve, by the heat exchanger and thanks the fixed setting by-pass which ensures an instantaneous production of DHW at the right temperature, avoiding water waste and delay.

Differential valve (adjustable flow from 520 l/h to 1.400 l/h) for balancing the flow of the modules indipendently to the head of the primary circuit.

 

ADVANTAGES

• High performance heat exchanger: high production of instantaneous domestic hot water with low supply primary temperature
• Minimized risk of lime scale and bacteria formation

 

rsd 001

MACUK RSD – Heat interface unit HIU – Energy Metering & Temperature Control

MACUK RSD is a substation for heating and instantaneous domestic hot water.

It is suitable for apartments, single family house and central heating systems. 

Heating function + DHW function.

Several accessories are available to fulfil all requirements.

- heat meter and cold water meter with pulse output M-Bus ready;
- heat meter and cold water meter with radio transmitter;
- ultrasonic heat meter;
- 230 V or 24 V electric actuators for differential valve.

The production of domestic hot water is controlled by a proportional thermostatic valve, by the heat exchanger and thanks the fixed setting by-pass which ensures an instantaneous production of DHW at the right temperature, avoiding water waste and delay.

Differential valve (adjustable flow from 400 l/h to 1.400 l/h) for balancing the flow of the modules indipendently to the head of the primary circuit.

 

ADVANTAGES

• High performance heat exchanger: high production of instantaneous domestic hot water with low supply primary temperature
• Minimized risk of lime scale and bacteria formation

 

s-sr nuovo 001

MACUK S-SR – Heat interface unit HIU – Energy Metering & Temperature Control

MACUK S-SR is a substation for heating and instantaneous domestic hot water with two plates heat exchangers: the first one to divide the primary circuit to the secondary circuit, the second one for DHW production. 

It is suitable for apartments, single family house and central heating systems.

Separation + Heating function + DHW function

Its installation is fast and easy. It is ready to be connected with the hydraulic connections on the premises.

 

Several accessories are available to fulfill all requirements.

- heat meter and cold water meter with pulse exit M-Bus ready
- heat meter and cold water meter with radio transmitter
- ultrasonic heat meter
- thermostatic kit 30-60°C suitable for low temperature heating systems
- electronic control kit consisting of: electric servomotor 230V, digital heating controller and remote control with room sensor.

The production of domestic hot water is controlled by a thermostatic valve, by the heat exchanger and thanks the 2-way proportional valve which ensures an instantaneous production of DHW at the right temperature, avoiding water waste and delay.

 

ADVANTAGES

• High performance heat exchanger: high production of instantaneous domestic hot water with low supply primary temperature

• Minimized risk of lime scale and bacteria formation

 • Adjustable setting differential valve in the primary circuit. It keeps the pressure constant in the secondary circuits

 • Total separation of the primary/secondary circuits

 

CONTABILIZZAZIONE

M-BUS ENERGY METERING

EYRON

EYRON – M-BUS COMPACT ENERGY METERING

NEW 2014

LOVATO EYRON
COMPACT ENERGY METERING.

“EYRON” energy metering systems are electronic devices with microprocessor made of a single-jet volumetric meter.

The meters, connected to temperature and volume sensors, can measure the energy used for heating or cooling the rooms and the volume of domestic hot or cold water. They can also store relevant data and make them available for cost subdivisions.

Furthermore they are certified according to the law EN 1434 and they have the MID certification.

MIDE CERTIFICATO ROSSO

For energy metering, two temperature sensors (supply and return) and water meter are necessary.

This one collects data relative to the flow rate, while Δt is measured by PT 500 temperature sensors.

2 further signals may be linked to EYRON meter, usually data coming from volumetric meters for hot and cold domestic water.

 

ADVANTAGES

• Measurement of heating or heating/cooling
• Single-jet volumetric system
• 2 sensors PT500 included and already coupled (L=1,5 m)
• Temperature return sensor integrated in the volumetric system
• Compact design
• Simple and intuitive menu
• 8 numbers LCD display, 3 decimals and special symbols visualisation
• A user button on the front
• Possibility to check data relative to previous 15 months
• High frequency volumetric pulse pump for a better precision
• Optical interface put in as standard
• Possibility to meter at the same time 2 further volumetric meters (volume HSW and CSW)
• Possibility to set up to two custom pulse output
• Battery life: 6 years +1, over 10 years if fed via Bus by data logger (M-Bus solution only) and M-Bus ultrasonic

 


EYRON

• EYRON MEC CFMS M-BUS
Qn 1,5 m3/h – 110×3/4” – CL3

• EYRON MEC CFRS RADIO
Qn 1,5 m3/h – 110×3/4” – CL3

• EYRON ULTRA CFMUS ULTRASONIC
Qn 1,5 m3/h – 110×3/4” – CL2

• EYRON ULTRA CFRUS RADIO ULTRASONIC
Qn 1,5 m3/h – 110×3/4” – CL2

• EYRON MEC CFRS RADIO
Qn 2,5 m3/h – 130×1” – CL3d

• EYRON ULTRA CFMUS ULTRASONIC
Qn 2,5 m3/h – 130×1” – CL2

• EYRON ULTRA CFRUS RADIO ULTRASONIC
Qn 2,5 m3/h – 130×1” – CL2

• EYRON ULTRA CFMUS ULTRASONIC
Qn 3,5 m3/h – 150×1” 1/4 – CL2

• EYRON ULTRA CFRUS RADIO ULTRASONIC
Qn 3,5 m3/h – 150×1” 1/4 – CL2

 

Contabilizzatore LVT5

LVT/5 – MBUS COAXIAL ENERGY METERING

LOVATO LVT/5
COAXIAL ENERGY METERING.

“LVT/5” energy meter are electronic devices with microprocessor composed of a multi-jet volumetric meter. 

The device, connected to volume/temperature sensors, are able to meter the energy involved in room heating and cooling and the volumes of hot and cold sanitary water of 3 different volumetric meters, to store relevant data and make them available for costs subdivisions.

Moreover they have the compliance certification according to EN 1434 regulation and MID certification.

MIDE CERTIFICATO ROSSO

In order to meter the water consumptions the following devices are necessary: an EAS support, where the vector fluid flows, a LVT/5 meter and two temperature sensors supply and return) connected to the meter.

The latter, through EAS support, collects flow-rate data, while Δt is measured by PT500 temperature sensors.

3 additional signals may be connected to LVT/5 meter, usually data from volumetric meters for domestic cold and hot water.

 

ADVANTAGES

• Installation on EAS support
• Measurement of heating or heating/cooling
• Multi-jet volumetric system
• 2 sensors PT500 included and already coupled (L=1,5 m)
• Temperature return sensor integrated in the volumetric system
• Compact design and coaxial connection
• Simple and intuitive menu
• 8 numbers LCD display, 3 decimals and special symbols visualisation
• A user button on the front
• Possibility to check data relative to previous 18 months
• High frequency volumetric pulse pump for a better precision
• Optical interface put in as standard
• Possibility to count at the same time 3 further volumetric pumps (volume DHW and DCW)
• Possibility to set up to three custom pulse output
• Battery life: 6 years (over 10 years if fed via Bus by data logger)

MULTIDATA LOVATO WR3

WR3 MULTIDATA – Metering system in boiler room

Multidata WR3 is a metering unit controlled by a state-of-the-art microprocessor.

This measuring system allows, when combined with PT500 temperature sensors, to obtain the best measuring precision and stability.

The metering unit has been produced using the modern SMD technology.

A NEC microprocessor of the 75X series guarantees the energy efficiency inside the counter for over 6 years.

 

MULTIDATA_SCHEME

 

Both common volumetric counters with Reed switches and high-frequency electronic counters may be connected to the volume entries. Multidata WR3 may obviously work  with every volume rate. In case of compact devices, most of all volumetric counters intended as single stream counters, the counting unit may be separated from the device and hung to the wall. 

The multiplejet version and Woltmann version are designed only for the wall-assembling.  Malfunctioning are automatically identified and can be shown in the display, with date, duration and malfunction type.

The not working times are memorised and may be consulted in case of check-up. A memory guarantees, on regular time intervals, that all main data do not get lost. Moreover every device is equipped with an optical interface for mobile reading and for main parameters programming. All standard unit can be connected to 2 additional pulsers, e.g. a cold and hot water meter, the metering can be read on the display and can be measured from the read-out system.

Further versions for every measurement requirements are available: in this way it is possible to feed and select a greater quantity of devices through M-bus system. The heat meter is already set for data air transmission.

 

 

 

 

 

 

CONTABILIZZAZIONE

Energy metering in boiler room

KIT BE-Q CK-D

BE-Q CK-D – Counting kit KA DN25 / KS DN25

NEW 2014

Be-Q CK ultrasonic metering kit may be combined with DN25 systems and is suitable for energy metering in every single zone of a centralised context.

It is especially recommended in four-family buildings or semidetacked or in every context which requires costs subdivision for each housing unit.

It is composed of an ultrasonic meter of 2,5 m3/h, reduction kit for the connection to the distribution units, check valve, sendor pocket kit (delivery) M10x1,5, spacer connection 90 mm in the Be-Q CK-D model.

> KA DN25 e KS DN25

LOVATO EYRON ULTRA CFMUS

BE-Q CK 2 BE-Q CK 3

 

BE-Q CK-M

BE-Q CK-M – Counting kit KTC DN25 / KM3 DN25

NEW 2014

Be-Q CK ultrasonic metering kit may be combined with DN25 systems and is suitable for energy metering in every single zone of a centralised context.

It is especially recommended in four-family buildings or semidetacked or in every context which requires costs subdivision for each housing unit.

It is composed of an ultrasonic meter of 2,5 m3/h, reduction kit for the connection to the distribution units, check valve, sendor pocket kit (delivery) M10x1,5, spacer connection 90 mm in the Be-Q CK-D model.

> KTC DN25 / KM3 DN25

LOVATO EYRON ULTRA CFMUS

BE-Q CK 1

 

ENERGY COUNTER KIT ULTRASONIC

ULTRASONIC Energy Counter KIT MID Directive

ENERGY COUNTER KIT ULTRASONIC 

The kit of heating/cooling meter is composed of:

– multi-jet volumetric ultrasonic meter with dry dial and reed pulse exit, suitable for horizontal and vertical installation

– Electronic metering unit

– Couple of probes PT500, wire length1,5 m and sensor pocket

ENERGY KIT FLANGIATO

ULTRASONIC Energy Counter KIT MID Directive

ENERGY COUNTER KIT ULTRASONIC 

The kit of heating/cooling meter is composed of:

– multi-jet volumetric ultrasonic meter with dry dial and reed pulse exit, suitable for horizontal and vertical installation

– Electronic metering unit

– Couple of probes PT500, wire length1,5 m and sensor pocket

ENERGY KIT

Mthisplit – Energy Counter KIT MID Directive

ENERGY COUNTER KIT – MID DIRECTIVE

The kit of heating/cooling meter is composed of:

– multi-jet volumetric meter with dry dial and reed pulse output, suitable for horizontal and vertical installation

– Multidata WR3 metering unit

– 2 sensors PT500, wire length 1,5 m and sensor pocket

 

• ENERGY COUNTER KIT – MID DIRECTIVE – Qn 2,5 m3/h – DN20 – 190 mm
• ENERGY COUNTER KIT – MID DIRECTIVE – Qn 3,5 m3/h – DN25 – 260 mm
• ENERGY COUNTER KIT – MID DIRECTIVE – Qn 6 m3/h – DN25 – 260 mm
• ENERGY COUNTER KIT – MID DIRECTIVE – Qn 6 m3/h – DN32 – 260 mm
• ENERGY COUNTER KIT – MID DIRECTIVE – Qn 10 m3/h – DN40 – 300 mm

Volumetrico ACS

SINGLE-JET VOLUMETRIC METER FOR DOMESTIC HOT WATER

SINGLE-JET VOLUMETRIC METER FOR DOMESTIC HOT WATER

MID DIRECTIVE

Single jet volumetric meter with dry dial for domestic hot water with pulse output

Horizontal and vertical assembling possible

 

CONTATORE VOL AFS

SINGLE-JET VOLUMETRIC METER FOR DOMESTIC COLD WATER

SINGLE-JET VOLUMETRIC METER FOR DOMESTIC COLD WATER

Single-jet volumetric meter with dry dial for domestic hot water with pulse output

Horizontal and vertical assembling possible

CONTATORE VOLUMETRICO ACS LITTL

MULTI-JET VOLUMETRIC METER FOR DOMESTIC HOT WATER

MULTI-JET VOLUMETRIC METER FOR DOMESTIC HOT WATER

Multi-jet volumetric meter with dry dial and reed pulse output

Timer with 5 rollers

Horizontal and vertical assembling possible

 

CONTATORE VOLUMETRICO AFS BIG

MULTI-JET VOLUMETRIC METER FOR DOMESTIC COLD WATER

MULTI-JET VOLUMETRIC METER FOR DOMESTIC COLD WATER

 MID DIRECTIVE

Multi-jet volumetric meter with dry dial and reed pulse output

Timer with 5 rollers

Horizontal and vertical assembling possible

AFS ACS BASIC

VOLUMETRIC METERS BASIC FOR HOT/COLD DOMESTIC WATER

VOLUMETRIC METERS BASIC FOR HOT/COLD DOMESTIC WATER

Single-jet volumetric meter, dry dial, magnetic transmission

Ready for further installation of a direct or radio M-Bus emitter

• DHW BASIC
Temp max 90 °C  Qn 1,5 m3/h

• DCW BASIC
Temp max 50 °C  Qn 1,5 m3/h

 

 

Sensore induttivo 1

 

Radio module 868 MHz Wireless M-Bus, with integrated inductive sensor for BASIC meters

The radio interface is already configured, it is supplied disabled and it activates itself automatically once the module is installed on the meter

 

Sensore induttivo 2

 

Compact M-Bus module with integrated inductive sensor for BASIC water meters 

Contatore Volumetrico ACS

VOLUMETRIC COUNTERS MULTI-JET WOLTMANN ACS

Contatori volumetrici FLANGIATI MULTIGETTO WOLTMANN 
per acqua calda sanitaria (ACS)

 

• Contatore volumetrico a mulinello Woltmann, meccanismo estraibile, quadrante asciutto, per acqua calda (ACS) fino a 90 °C.
• Versione dotata di emettitore Reed.
• Montaggio orizzontale o verticale.
• Prima verifica inclusa.

 

ENERGY KIT WOLTMANN

WOLTMANN – Energy Counter KIT MID Directive

ENERGY COUNTER KIT – WOLTMANN
MID DIRECTIVE

The kit of heating/cooling meter is composed of:

– multi-jet volumetric meter Woltmann pump with dry dial and reed pulse output, suitable for horizontal and vertical installation
– Multidata WR3 metering unit
– 2 sensors PT500, wire length 1,5 m and sensor pocket

 

• WOLTMANN – Energy Counter KIT MID Directive – Qn 15 m3/h – DN50 – 200 mm
• WOLTMANN – Energy Counter KIT MID Directive – Qn 25 m3/h – DN65 – 200 mm
• WOLTMANN – Energy Counter KIT MID Directive – Qn 40 m3/h – DN80 – 250 mm
• WOLTMANN – Energy Counter KIT MID Directive – Qn 60 m3/h – DN100 – 250 mm
• WOLTMANN – Energy Counter KIT MID Directive – Qn 100 m3/h – DN40 – 250 mm

ATATTATORE MBUS

M-BUS PULSE ADAPTER/CONVERTER MODULE

M-BUS PULSE ADAPTER/CONVERTER 

IMPULSE ADAPTER/CONVERTER M-BUS
ENERGY METERING IN BOILER ROOM

Impulse meter for application on the M-Bus line able to detect up to 2 pulse inputs

The device is fed by the same M-Bus network but it has anyway an internal backup battery

Standard configuration: 1 pulse/10 liters

Trasmettitore

RADIO PULSE ADAPTER/CONVERTER M-BUS

RADIO PULSE ADAPTER/CONVERTER M-BUS

2-way radio transmitter receiver which records the reading of the combined counter and transmits it via radio 868 MHz Wireless M-Bus.

ENERGY METERING IN BOILER ROOM

It may be combined with every kind of counter with pulse output

Internal lithium battery, 12 years duration

SONDE

Sensor pocket DN32/200

Sensor pocket DN32/200

• ½”X40 DN32/65 – 6 mm
• ½”X80 DN80/125 – 6 mm
• ½”X DN120/150/200 – 6 mm