DHW PRODUCTION MODULES

Lovato Spa
ie40TFAST - NEW
T-FAST ie40 COMPACT
BIG TFAST NEW
BIG T-FAST ie Stazione Produzione ACS
BUTTON T-FAST CONFIGURATOR
T-FAST CONFIGURATOR
mini ok
T-FAST MINI DHW PRODUCTION MODULE
LOVATO T-FAST i20_Moduli di Produzione ACS
T-FAST i20 DHW production module – INSTANT HOT WATER STATION
LOVATO T-FAST i35_Modulo di produzione ACS
T-FAST i35 DHW production module – INSTANT HOT WATER STATION
LOVATO_TFAST_ie60_NEW_2014_ACS_DHW
T-FAST ie60 DHW production module – INSTANT HOT WATER STATION
ie40TFAST - NEW

T-FAST ie40 COMPACT

COMING SOON

Vieni a vederlo in anteprima a:

MCE 2018
Fieramilano 13-16 marzo 2018
HALL 2 – STAND K33 L32

 

BIG TFAST NEW

BIG T-FAST ie Stazione Produzione ACS

COMING SOON

Vieni a vederlo in anteprima a:

MCE 2018
Fieramilano 13-16 marzo 2018
HALL 2 – STAND K33 L32

 

BUTTON T-FAST CONFIGURATOR

T-FAST CONFIGURATOR

BANNER T-FAST CONFIGURATOR 2

T-FAST CONFIGURATOR 1.0

For Domestic hot water producers LOVATO T-FAST

 

Size your system by a click with an easy and intuitive tools to determine in few seconds the right size of the buffer tank and the LOVATO T-FAST more suitable for your project.

 

TRY IT NOW FOR FREE!

 

The configurator has ben made with the maximum care according to science and knowledge. The data resulting from its use are indicative and not binding, they complete an existing project, developed in compliance with the regulations in force.
Lovato shall not be liable about the evaluation and the selection of the domestic hot water producer size that must be committed to the qualified personnel.
mini ok

T-FAST MINI DHW PRODUCTION MODULE

THE DHW “MICRO-PRODUCER”!

Compact dimensions, maximum result.

T-FAST MINI is a DHW production module that uses the working principle of a stainless steel plate heat exchanger.

The temperature of the water is managed by a thermostatic mixing valve on the primary circuit. The pump, placed on the primary circuit is activated
to the signal of the flowswitch that is placed on the secondary circuit. For optimized the comfort a secondary return kit is available.

T-FAST MINI is designed for the installation of the heat meter 1,5mc/h 110 x ¾.

• THERMOSTATIC MIXING VALVE
• HIGH EFFICIENCY PUMP
• ULTRA-COMPACT

OPTIONAL:
+ SECONDARY RETURN KIT
+ HEAT METERING


ADVANTAGES

- Compact module 330x450x120 white cover ral 9010
– Preassembled and tested module
– Wall-hung or built-in version
– Shut-off valves both on primary and secondary circuit
– Reduced maintenance
– Easy temperature setting
– Large production of DHW
– No need to balance the flow rate of the primary circuit
– Modulating flow rate by the thermostatic mixing valve on the primary circuit
– Available the secondary return kit
– Secondary return kit with return temperature setting
– Design for the installation of the heat meter (primary circuit)


WALL-HUNG VERSION and BUILT-IN VERSION

LOVATO - MINI ACS - PENSILE LOVATO - MINI ACS INCASSO

LOVATO T-FAST MINI – DHW PRODUCTION MODULE
• con Wilo YONOS PARA  ERP READY

 

EXAMPLES OF USE

 

SCHEMA DEU-ENG 1 MINI

 

 

EXAMPLES OF USE

 

MINI ENG EDU APPLICAZIONE 2

LOVATO T-FAST i20_Moduli di Produzione ACS

T-FAST i20 DHW production module – INSTANT HOT WATER STATION

T-FAST i20 is an instantaneous domestic hot water production module that uses the working principle of a stainless steel plates exchanger, that finds a wide use if coupled with buffer tanks.

The setting of the domestic hot water temperature is made through the regulation of the thermostatic actuator of the primary circuit mixing valve.

The primary circuit pump is controlled by means of a pressure switch electrically connected.

Is available a DHW recirculation pump kit.

 

ADVANTAGES – Fresh Hot Water Modules

• Domestic hot water is produced on requests, so that big accumulations are not necessary
• DHW nominal supply 20 l/min
• High performances thanks to the oversized plate exchanger made of steel
• High reduction of water stagnation and legionella risk
• Possibility to install domestic recirculation
• Installation on wall or directly on a tank
• Standard or high efficiency circulating pump
• Quick installation and easy maintenance
• It may be combined with each heat generator
• Complete with thermal insulation

• HIGH REDUCTION OF WATER STAGNATION AND LEGIONELLA RISK.

 

LOVATO T-FAST i20

 

Examples of use 

ie20 Schema di Funzionamento ACS4

LOVATO T-FAST i35_Modulo di produzione ACS

T-FAST i35 DHW production module – INSTANT HOT WATER STATION

T-FAST i35 is an instantaneous domestic hot water production module that uses the working principle of a stainless steel plates exchanger, that finds a wide use if coupled with buffer tanks.

The setting of the domestic hot water outlet temperature is made through the regulation of the thermostatic actuator of the primary circuit mixing valve.

The primary circuit pump is controlled by means of a pressure switch electrically connected.

Is available a DHW recirculation pump kit.

 

ADVANTAGES – Fresh Hot Water Modules

• Domestic hot water is produced on requests, so that big accumulations are not necessary
• DHW nominal supply 35 l/min
• High performances thanks to the oversized plate exchanger made of steel
• High reduction of water stagnation and legionella risk
• Possibility to install domestic recirculation
• Installation on wall or directly on a tank
• Standard or high efficiency circulating pump
• Quick installation and easy maintenance
• It may be combined with every heat generator
• Complete with thermal insulation

• HIGH REDUCTION OF WATER STAGNATION AND LEGIONELLA RISK.

 

LOVATO T-FAST i35

 

 

Examples of use 

ie35 Schema di Funzionamento ACS4

LOVATO_TFAST_ie60_NEW_2014_ACS_DHW

T-FAST ie60 DHW production module – INSTANT HOT WATER STATION

T-FAST-IE 60 is an instantaneous domestic hot water production module that uses the working principle of a stainless steel plates exchanger, that finds a wide use if coupled with buffer tanks.

The setting of the domestic hot water outlet temperature (secondary side) happens with the modulation of the primary circuit flow rate through a variable flow pump controlled by MFWC controller (PWM control).

The system, which works with a low primary temperature, finds a wide use in thermal solar systems and in underfloor heating.

3-way mixing valve: estabilishes the inlet water temperature (ideal function for the summer, in which the system exploites solar thermal panels)

Is available a DHW recirculation pump kit.

 

ADVANTAGES – Fresh Hot Water Modules

• Domestic hot water is produced on requests, so that big accumulations are not necessary
• DHW nominal supply 60 l/min
• High performances thanks to the oversized plate exchanger made of steel
• High reduction of water stagnation and legionella risk
• Possibility to install domestic recirculation
• Standard or high efficiency circulating pump
• Quick installation and easy maintenance
• It may be combined with every heat generator
• Complete with thermal insulation

• HIGH REDUCTION OF WATER STAGNATION AND LEGIONELLA RISK.

 

LOVATO T-FAST ie 60

• Wilo STRATOS PARA 25/1-11 ERP READY

Max working pressure 6 bar – DHW temperature set 30-90 °C


 

Examples of use

ie60 Schema di Funzionamento ACS4